top of page

Xgard Bright (Please call for price)

Xgard Bright

Meet the next generation of flammable gas detection. 

Xgard Bright is a versatile platform offering flammable and toxic gas detection and oxygen monitoring, while providing ease of operation and reduced installation costs.

Providing analogue 4-20mA and RS-485 Modbus signals as standard, Xgard Bright comes with an Alarm and Fault relay as standard as well as optional HART communications.

Lowering the cost of installation, the 4-wire addressable implementation drastically reduces cabling requirements. The large OLED display allows users to easily work with Xgard Bright during install, calibration and routine maintenance without the need to open the housing.

The Xgard Bright is now available with MPS (Molecular Property Spectometer™) technology.

Wide range of new gases and sensor types are now available and have been added to the configurator.

If you cannot see your gas or range required, please contact Crowcon to discuss options.

  • Specifications

    Specifications

    Size 156 x 166 x 109mm (6.1 x 6.5 x 4.3inch)
    Cable Entry 2x M20 (stopping plug fitted to left-side entry)
    Power 10-30Vdc. 3W max
    Electrical Output 4-20mA current sink or source
    RS-485 Modbus RTU
    HART (Optional)
    Weight Aluminium alloy 1kg (2.2lbs)
    Enclosure Material ADC 12 aluminium alloy
    Relay Alarm 1, Alarm 2, Fault

     

    SPST contacts rated 1A 30Vdc

    Sounder Out 24Vdc (nominally), 250mA maximum load
    Operating Temperature -40°C to +70°C (-40°F to 158°F)

     

    Note: sensor operating temperatures vary widely.

    Refer to the sensor module datasheet or contact

    Crowcon for specific sensor data.

    Humidity 0 to 95% RH, non-condensing
    Repeatability +/- 2% FSD
    Zero drift +/- 2% FSD per year maximum
    Ingress protection IP65 (IP66 with weatherproof cap)
    Approvals ATEX and IECExEx II 2 G Ex db IIC T6 Gb

     

    Ex tb IIIC T80ᶜ Db

    II 2 G Ex db IIC T6 Gb

    II 2 D Ex tb IIIC T80ᶜ Db

    Certificate numbers:

    TUV 16 ATEX 7908 X

    IECEx TUR16.0035 X

    EMC Compliance EN50270: 2015
    Standards EN60079-0 :2012 + A11:2013
    EN60079-1 :2014
    IEC60079-0 :2011 Edition 6
    IEC60079-1 :2014 Edition 7
    Zones Certified for use in Zone 1 and Zone 2 areas

    Gases and Ranges

    Gas Units Max
    Range
    Standard
    Range
    Alarm 1
    level
    Alarm 2
    level
    Temp
    range °C 
    MPS Flam %LEL 100 100 20 40 -40 to +75
    Oxygen (O2) %Vol 30 25 19 (falling) 17 (falling) -20 to +50
    Carbon Monoxide (CO) PPM 1000 250 30 200 -30 to +50
    Hydrogen Sulphide (H2S) PPM 100/200 25 5 10  -30 to +50
    Hydrogen (H2) %LEL 100 100 20 40 -40 to +75
    Methane (CH4) %LEL 100 100 20 40 -40 to +75
    Pentane (C5H12) %LEL 100 100 20 40 -40 to +75
    LPG %LEL 100 100 20 40 -40 to +75
    Carbon Dioxide (CO2) %VOL 0-5% 0-5% 0-2% 0-3% -20 to +50
    PID (VOC) – Safe Area PPM 1000 1000 30 50 -20 to +50
    Infra Red Methane (CH4) %LEL 100 100 20 40 -40 to +75
    Infra Red Propane (C3H8) %LEL 100 100 20 40 -40 to +75
    Ammonia (NH3) – Safe Area PPM 100 50 25 25 -20 to +40
    Chlorine (CL2) – Safe Area PPM 10 5 1 3 -20 to +40
    Ozone (O3) – Safe Area PPM 1 1 0.1 0.2 -20 to +40
    Sulphur Dioxide (SO2) – Safe Area PPM 100 10 1 1 -30 to +50
    Infra Red Butane (C4H10) %LEL 100 100 20 40 -40 to +75
    Infra Red Pentane (C5H12) %LEL 100 100 20 40 -40 to +75
    Infra Red LPG %LEL 100 100 20 40 -20 to +55
  • Delivery & Returns

    Information on delivery and returns can be found on our Delivery and Returns Policy page.

£0.00Price
bottom of page