Xgard (Please call for price)
Overview
Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX and UL.
Low cost of ownership
- Designed for easy installation and maintenance – keeps costs down
- Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
- Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum
Flexible installation options
- The Xgard multi gas detectors are designed for either wall or ceiling mounting – no need for additional brackets
- Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
- High temperature models are available for hot environments (up to 150oc)
- Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking
Wide range of sensors
- Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
- Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
- Thermal conductivity sensors are available to monitor % volume concentrations of gases
Rugged and reliable
- Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
- Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
- All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)
Specifications
Specifications
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Xsafe Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) Weight Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) 1.5 kg (3.3lbs) Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) 1kg (2.2lbs) Enclosure material ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Aluminium or 316 Stainless Steel Aluminium Aluminium or 316 Stainless Steel Aluminium Ingress protection IP65 IP54 IP65 Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side Terminations 0.5 to 2.5mm2 Sensor type Electrochemical Catalytic bead 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductivity Catalytic bead Operating temperature -20 to +50 °C
(-4 to 122 °F)
(sensor dependant)-20 to +50°C (-4 to 122°F) -40 to +80°C
(-40 to 176°F)-20 to +150°C (-4 to 302°F) -40 to +55°C (-40 to 131°F) +10 to +55°C (50 to 301°F) mV: -40 to +80oC (-40 to 176oF)
mA: -40 to +55oC (-40 to 131oFHumidity 10 to 95% RH non-condensing 0-99% RH non-condensing 0-90% RH 0-99% RH Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical) Response time T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) T90 <15s (Typical) Operating voltage 8-30V dc 2.0V dc +/- 0.1V (Typical) 10-30V dc mA: 10- 30V dc mV:2.0Vdc Power requirements 24mA maximum 300mA (Typical) 50mA at 24V dc 1.2W MA:50mA at 24V dc 1.2W mV: 300mA (Typical) Electrical output 2- wire 4-20mA (current sink) 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 3- wire 4-20mA (current sink or source) mA: 3- wire 4-20mA (current sink or source) mV: 3- wire mV bridge
Typical signal: 12-15mV/ %LEL CH4Approvals ATEX: II 1 G
Exia IIC T4 Ga
(Tamb -40 to +55°C)
UL/cUL: Class I, Div. 1
Groups A, B, C, D
IECExATEX: II 2GD
Exd IIC T6 Gb (Tamb -40 to +50°C)
UL: Class I, Div. 1
Groups B, C, D
IECExATEX: II 2 GD
Exd IIC T4 Gb
(Tamb -40 to +80°C)
Exd IIC T6 Gb (Tamb -40 to +50°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECExATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)
Exd IIC T4 Gb (Tamb -40 to +80°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECExEMC compliance EN 50270 FCC Part 15 ICES- 003 *3/4 ” cable entry only available on aluminium juntion boxes.
Delivery & Returns
Information on delivery and returns can be found on our Delivery and Returns Policy page.