XgardIQ (Please call for price)
Overview
XgardIQ is an intelligent and versatile fixed detector and transmitter compatible with Crowcon’s full range of sensor technologies. Available fitted with a variety of sensors for fixed flammable, toxic, oxygen or H2S gas detection.
Providing analogue 4-20mA and RS-485 Modbus signals as standard, XgardIQ is optionally available with Alarm and Fault relays and HART communications. The 316 stainless steel are available with three M20 or 1/2“NPT cable entries.
(SIL-2) Safety integrity level 2 certified fixed detector.
Easy and safe to use
OLED Display – Bright, clear display indicates gas level and detector status even in dark locations
Non-Intrusive Calibration – Zero and calibration functions are performed via the display and keypad, without the need for a hot-work permit or any special tools (e.g. no magnetic wand required)
+Ve Safety Indicator – Confirms the detector is operating safely at a glance
Event Log Function – Stores all alarm, fault and maintenance events to provide a history of detector use
Remote Sensor – Improves probability of detection
Simple installation and maintenance
Universal Transmitter – Common transmitter for Crowcon’s full range of sensor technologies
Hot-Swap Sensor Modules – Sensors can easily be replaced using one hand without requiring tools or a hot-work permit
Auto-Sense Function – Automatically detects whether the control system is 4-20mA current sink or source and sets itself appropriately, eliminating the risk of being incorrectly set
Auto-Configure Function – Detects when a sensor module is plugged-in and uploads the appropriate gas type, range, units and alarm levels
Reliability
Smart Bump And Speedy Bump Test Functions – Enable sensor health and response to be verified quickly and easily using test gas. Process is automated and provides a reminder when a bump test is due
Calibration Due Warning – Reminds the user when calibration is due to ensure that sensors remain operational and accurate at all times
Sensor Range Selection – User can set the full-scale range of the sensor via the display menu according to site or specific location requirements.
Specifications
Specifications
Size
H278 x W140 x D89mm (10.9 x 5.5 x 3.5 in)
Weight
4.1Kg (9lbs)
Enclosure material
316 stainless steel
Ingress protection
IP66
Connection
Three M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries
Power
14-30 VDC. <4W
Display
Main display – OLED 128 x 64 pixels, yellow text on black background Indicators – Amber, Red and Green LED’s for detector status; Blue +ve Safety LED
Electrical output
4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant RS-485 Modbus RTU HART 7 over 4-20mA signal and via local I.S. test points (optional) Relays (optional) Alarm 1, Alarm 2, Fault SPCO contacts rated 5A, 230Vac Relay configuration options Energised or de-energised Latching or non-latching Rising or falling Configurable On and Off delays on alarm relays.
Event logging
Records alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC.
Operating temperature
Transmitter only: -40°C to +75°C (-40°F to +167°F)†
Sensor type:
Oxygen: (-20°C to +50°C ambient) Toxic: (-40°C to +50°C ambient) Pellister: (-40°C to +75°C ambient) Infra-red (IR): (-20°C to +55°C ambient) High temperature toxic: (-40⁰C to +70⁰C)
Humidity
0 to 95% RH non-condensing†
Repeatability
+/- 2% FSD
Zero drift
+/- 2% FSD per year maximum
Response time
Sensor dependant: contact Crowcon for specific sensor data.
Approvals
ATEX and IECEx: Ex II 2 G Ex db ia IIC T4 Gb (see above for temperature ranges)
Performance
Designed for compliance with: EN50104 (oxygen sensors) EN45544 (toxic gas sensors)* EN50271 (software) H2S performance standard
Functional safety
IEC61508, EN50402 SIL 2
EMC Compliance
EN50270:2015 FCC CFR47 Part 15B ICES-003
† Note: sensor operating temperature and humidity limits vary widely.
* Features outstanding at the time of issue, contact Crowcon for details.
Gases and Ranges
Gas
Units
Max Range
Standard Range
Alarm 1 level
Alarm 2 level
Temp range °C
Oxygen (O2)
%Vol
30
25
19 (falling)
17 (falling)
-20 to +50
Ammonia
PPM
100/1000
50
25
35
-20 to +40
Carbon Monoxide (CO)
PPM
1000
250
30
200
-30 to +50
Hydrogen Fluoride (HF)
PPM
10
10
1.8
3
+5 to +40
Hydrogen Sulphide (H2S)
PPM
100/200
25
5
10
-30 to +50
High Temperature Hydrogen Sulphide (H2S)
PPM
100/200
25
5
10
-40 to +70
Ozone (O3)
PPM
1
1
0.1
0.2
-20 to +40
Sulphur Dioxide (SO2)
PPM
100
10
1
1
-30 to +50
Hydrogen (H2)
%LEL
100
100
20
40
-40 to +75
Methane (CH4)
%LEL
100
100
20
40
-40 to +75
Pentane (C5H12)
%LEL
100
100
20
40
-40 to +75
Propane (C3H8)
%LEL
100
100
20
40
-40 to +75
Ethanol (IR sensor)
%LEL
100
100
20
40
-20 to +55
LPG (IR sensor)
%LEL
100
100
20
40
-20 to +55
Methane (IR sensor)
%LEL
100
100
20
40
-20 to +55
Propane (IR sensor)
%LEL
100
100
20
40
+10 to + 55
Delivery & Returns