top of page
XgardIQ  (Please call for price)

XgardIQ (Please call for price)

Overview

XgardIQ is an intelligent and versatile fixed detector and transmitter compatible with Crowcon’s full range of sensor technologies. Available fitted with a variety of sensors for fixed flammable, toxic, oxygen or H2S gas detection.

Providing analogue 4-20mA and RS-485 Modbus signals as standard, XgardIQ is optionally available with Alarm and Fault relays and HART communications. The 316 stainless steel are available with three M20 or 1/2“NPT cable entries.

(SIL-2) Safety integrity level 2 certified fixed detector.

Easy and safe to use

  • OLED Display – Bright, clear display indicates gas level and detector status even in dark locations

  • Non-Intrusive Calibration – Zero and calibration functions are performed via the display and keypad, without the need for a hot-work permit or any special tools (e.g. no magnetic wand required)

  • +Ve Safety Indicator – Confirms the detector is operating safely at a glance

  • Event Log Function – Stores all alarm, fault and maintenance events to provide a history of detector use

  • Remote Sensor – Improves probability of detection

Simple installation and maintenance

  • Universal Transmitter – Common transmitter for Crowcon’s full range of sensor technologies

  • Hot-Swap Sensor Modules – Sensors can easily be replaced using one hand without requiring tools or a hot-work permit

  • Auto-Sense Function – Automatically detects whether the control system is 4-20mA current sink or source and sets itself appropriately, eliminating the risk of being incorrectly set

  • Auto-Configure Function – Detects when a sensor module is plugged-in and uploads the appropriate gas type, range, units and alarm levels

Reliability

  • Smart Bump And Speedy Bump Test Functions – Enable sensor health and response to be verified quickly and easily using test gas. Process is automated and provides a reminder when a bump test is due

  • Calibration Due Warning – Reminds the user when calibration is due to ensure that sensors remain operational and accurate at all times

  • Sensor Range Selection – User can set the full-scale range of the sensor via the display menu according to site or specific location requirements.

  • Specifications

    Specifications

    Size

    H278 x W140 x D89mm (10.9 x 5.5 x 3.5 in)

    Weight

    4.1Kg (9lbs)

    Enclosure material

    316 stainless steel

    Ingress protection

    IP66

    Connection

    Three M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries

    Power

    14-30 VDC. <4W

    Display

    Main display – OLED 128 x 64 pixels, yellow text on black background Indicators – Amber, Red and Green LED’s for detector status; Blue +ve Safety LED

    Electrical output

    4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant RS-485 Modbus RTU HART 7 over 4-20mA signal and via local I.S. test points (optional) Relays (optional) Alarm 1, Alarm 2, Fault SPCO contacts rated 5A, 230Vac Relay configuration options Energised or de-energised Latching or non-latching Rising or falling Configurable On and Off delays on alarm relays.

    Event logging

    Records alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC.

    Operating temperature

    Transmitter only: -40°C to +75°C (-40°F to +167°F)†

     

    Sensor type:

    Oxygen: (-20°C to +50°C ambient) Toxic: (-40°C to +50°C ambient) Pellister: (-40°C to +75°C ambient) Infra-red (IR): (-20°C to +55°C ambient) High temperature toxic:  (-40⁰C to +70⁰C)

    Humidity

    0 to 95% RH non-condensing†

    Repeatability

    +/- 2% FSD

    Zero drift

    +/- 2% FSD per year maximum

    Response time

    Sensor dependant: contact Crowcon for specific sensor data.

    Approvals

    ATEX and IECEx: Ex II 2 G    Ex db ia IIC T4 Gb (see above for temperature ranges)

    Performance

    Designed for compliance with: EN50104 (oxygen sensors) EN45544 (toxic gas sensors)* EN50271 (software) H2S performance standard

    Functional safety

    IEC61508, EN50402 SIL 2

    EMC Compliance

    EN50270:2015 FCC CFR47 Part 15B ICES-003

    † Note: sensor operating temperature and humidity limits vary widely.

    * Features outstanding at the time of issue, contact Crowcon for details.

    Gases and Ranges

    Gas

    Units

    Max Range

    Standard Range

    Alarm 1 level

    Alarm 2 level

    Temp range °C 

    Oxygen (O2)

    %Vol

    30

    25

    19 (falling)

    17 (falling)

    -20 to +50

    Ammonia

    PPM

    100/1000

    50

    25

    35

    -20 to +40

     Carbon Monoxide (CO)

    PPM

    1000

    250

    30

    200

     -30 to +50

    Hydrogen Fluoride (HF)

    PPM

    10

    10

    1.8

    3

    +5 to +40

    Hydrogen Sulphide (H2S)

    PPM

    100/200

    25

    5

    10

    -30 to +50

    High Temperature Hydrogen Sulphide (H2S)

    PPM

    100/200

    25

    5

    10

    -40 to +70

    Ozone (O3)

    PPM

    1

    1

    0.1

    0.2

    -20 to +40

    Sulphur Dioxide (SO2)

    PPM

    100

    10

    1

    1

    -30 to +50

    Hydrogen (H2)

    %LEL

    100

    100

    20

    40

    -40 to +75

    Methane (CH4)

    %LEL

    100

    100

    20

    40

    -40 to +75

    Pentane (C5H12)

    %LEL

    100

    100

    20

    40

    -40 to +75

    Propane (C3H8)

    %LEL

    100

    100

    20

    40

    -40 to +75

    Ethanol (IR sensor)

    %LEL

    100

    100

    20

    40

    -20 to +55

    LPG (IR sensor)

    %LEL

    100

    100

    20

    40

    -20 to +55

    Methane (IR sensor)

    %LEL

    100

    100

    20

    40

    -20 to +55

    Propane (IR sensor)

    %LEL

    100

    100

    20

    40

    +10 to + 55

  • Delivery & Returns

    Information on delivery and returns can be found on our Delivery and Returns Policy page.

£0.00Price